Back to Ricerca

Cable reels

Electricity

Cable reels

Those RAASM cable reels with an extension allow for the connection of electric tools and systems of between 230 V and 400 V, with and without Schuko socket. Available in different lengths and with accessories including a rewinding clutch, bayonet bracket and protection hood, these items are indispensable when it comes to keeping a work environment safe and organised. All models also have a heat guard and hose guide with 4 rollers as standard, and are certified with an electrical parts protection grade equal to IP44.

Cable reels


Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A21171
230 V single phase
IP44
-5 ÷ +40
2
2x1 - H05 VV-F
17 + 1
1,2
0,9
1,4
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.A21171
230 V single phase
IP44
-5 ÷ +40
2
2x1 - H05 VV-F
17 + 1
1,2
0,9
1,4
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.A21171
230 V single phase
IP45
-5 ÷ +40
2
2x1 - H05 VV-F
17 + 1
1,2
0,9
1,4
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.A21171
230 V single phase
IP44
-5 ÷ +40
2
2x1 - H05 VV-F
17 + 1
1,2
0,9
1,4
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.A21171
230 V single phase
IP45
-5 ÷ +40
2
2x1 - H05 VV-F
17 + 1
1,2
0,9
1,4
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.A21171
230 V single phase
IP44
-5 ÷ +40
2
2x1 - H05 VV-F
17 + 1
1,2
0,9
1,4
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.A21171
230 V single phase
IP45
-5 ÷ +40
2
2x1 - H05 VV-F
17 + 1
1,2
0,9
1,4
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.A21171
230 V single phase
IP45
-5 ÷ +40
2
2x1 - H05 VV-F
17 + 1
1,2
0,9
1,4
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.B21121
230 V single phase
IP44
-5 ÷ +40
2
2x1 - H07 RN-F
12 + 1
1,2
0,9
1,4
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.B21121
230 V single phase
IP44
-5 ÷ +40
2
2x1 - H07 RN-F
12 + 1
1,2
0,9
1,4
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.B21121
230 V single phase
IP45
-5 ÷ +40
2
2x1 - H07 RN-F
12 + 1
1,2
0,9
1,4
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.B21121
230 V single phase
IP44
-5 ÷ +40
2
2x1 - H07 RN-F
12 + 1
1,2
0,9
1,4
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.B21121
230 V single phase
IP45
-5 ÷ +40
2
2x1 - H07 RN-F
12 + 1
1,2
0,9
1,4
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.B21121
230 V single phase
IP44
-5 ÷ +40
2
2x1 - H07 RN-F
12 + 1
1,2
0,9
1,4
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.B21121
230 V single phase
IP45
-5 ÷ +40
2
2x1 - H07 RN-F
12 + 1
1,2
0,9
1,4
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.B21121
230 V single phase
IP45
-5 ÷ +40
2
2x1 - H07 RN-F
12 + 1
1,2
0,9
1,4
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A22151
230 V single phase
IP44
-5 ÷ +40
2
2x1,5 - H05 VV-F
15 + 1
1,2
1,1
2,3
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.A22151
230 V single phase
IP44
-5 ÷ +40
2
2x1,5 - H05 VV-F
15 + 1
1,2
1,1
2,3
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.A22151
230 V single phase
IP45
-5 ÷ +40
2
2x1,5 - H05 VV-F
15 + 1
1,2
1,1
2,3
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.A22151
230 V single phase
IP44
-5 ÷ +40
2
2x1,5 - H05 VV-F
15 + 1
1,2
1,1
2,3
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.A22151
230 V single phase
IP45
-5 ÷ +40
2
2x1,5 - H05 VV-F
15 + 1
1,2
1,1
2,3
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.A22151
230 V single phase
IP44
-5 ÷ +40
2
2x1,5 - H05 VV-F
15 + 1
1,2
1,1
2,3
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.A22151
230 V single phase
IP45
-5 ÷ +40
2
2x1,5 - H05 VV-F
15 + 1
1,2
1,1
2,3
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.A22151
230 V single phase
IP45
-5 ÷ +40
2
2x1,5 - H05 VV-F
15 + 1
1,2
1,1
2,3
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A23101
230 V single phase
IP44
-5 ÷ +40
2
2x2,5 - H05 VV-F
10 + 1
1,2
1,9
3,5
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.A23101
230 V single phase
IP44
-5 ÷ +40
2
2x2,5 - H05 VV-F
10 + 1
1,2
1,9
3,5
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.A23101
230 V single phase
IP45
-5 ÷ +40
2
2x2,5 - H05 VV-F
10 + 1
1,2
1,9
3,5
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.A23101
230 V single phase
IP44
-5 ÷ +40
2
2x2,5 - H05 VV-F
10 + 1
1,2
1,9
3,5
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.A23101
230 V single phase
IP45
-5 ÷ +40
2
2x2,5 - H05 VV-F
10 + 1
1,2
1,9
3,5
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.A23101
230 V single phase
IP44
-5 ÷ +40
2
2x2,5 - H05 VV-F
10 + 1
1,2
1,9
3,5
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.A23101
230 V single phase
IP45
-5 ÷ +40
2
2x2,5 - H05 VV-F
10 + 1
1,2
1,9
3,5
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.A23101
230 V single phase
IP45
-5 ÷ +40
2
2x2,5 - H05 VV-F
10 + 1
1,2
1,9
3,5
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A31141
230 V single phase
IP44
-5 ÷ +40
3
3Gx1 - H05 VV-F
14 + 1
1,2
0,9
1,4
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.A31141
230 V single phase
IP44
-5 ÷ +40
3
3Gx1 - H05 VV-F
14 + 1
1,2
0,9
1,4
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.A31141
230 V single phase
IP45
-5 ÷ +40
3
3Gx1 - H05 VV-F
14 + 1
1,2
0,9
1,4
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.A31141
230 V single phase
IP44
-5 ÷ +40
3
3Gx1 - H05 VV-F
14 + 1
1,2
0,9
1,4
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.A31141
230 V single phase
IP45
-5 ÷ +40
3
3Gx1 - H05 VV-F
14 + 1
1,2
0,9
1,4
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.A31141
230 V single phase
IP44
-5 ÷ +40
3
3Gx1 - H05 VV-F
14 + 1
1,2
0,9
1,4
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.A31141
230 V single phase
IP45
-5 ÷ +40
3
3Gx1 - H05 VV-F
14 + 1
1,2
0,9
1,4
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.A31141
230 V single phase
IP45
-5 ÷ +40
3
3Gx1 - H05 VV-F
14 + 1
1,2
0,9
1,4
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.B31101
230 V single phase
IP44
-5 ÷ +40
3
3Gx1 - H07 RN-F
10 + 1
1,2
0,9
1,4
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.B31101
230 V single phase
IP44
-5 ÷ +40
3
3Gx1 - H07 RN-F
10 + 1
1,2
0,9
1,4
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.B31101
230 V single phase
IP45
-5 ÷ +40
3
3Gx1 - H07 RN-F
10 + 1
1,2
0,9
1,4
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.B31101
230 V single phase
IP44
-5 ÷ +40
3
3Gx1 - H07 RN-F
10 + 1
1,2
0,9
1,4
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.B31101
230 V single phase
IP45
-5 ÷ +40
3
3Gx1 - H07 RN-F
10 + 1
1,2
0,9
1,4
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.B31101
230 V single phase
IP44
-5 ÷ +40
3
3Gx1 - H07 RN-F
10 + 1
1,2
0,9
1,4
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.B31101
230 V single phase
IP45
-5 ÷ +40
3
3Gx1 - H07 RN-F
10 + 1
1,2
0,9
1,4
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.B31101
230 V single phase
IP45
-5 ÷ +40
3
3Gx1 - H07 RN-F
10 + 1
1,2
0,9
1,4
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A32141
230 V single phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.A32141
230 V single phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.A32141
230 V single phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.A32141
230 V single phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.A32141
230 V single phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.A32141
230 V single phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.A32141
230 V single phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.A32141
230 V single phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.B32091
230 V single phase
IP44
-5 ÷ +40
3
3Gx1,5 - H07 RN-F
9 + 1
1,2
1,2
2,3
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.B32091
230 V single phase
IP44
-5 ÷ +40
3
3Gx1,5 - H07 RN-F
9 + 1
1,2
1,2
2,3
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.B32091
230 V single phase
IP45
-5 ÷ +40
3
3Gx1,5 - H07 RN-F
9 + 1
1,2
1,2
2,3
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.B32091
230 V single phase
IP44
-5 ÷ +40
3
3Gx1,5 - H07 RN-F
9 + 1
1,2
1,2
2,3
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.B32091
230 V single phase
IP45
-5 ÷ +40
3
3Gx1,5 - H07 RN-F
9 + 1
1,2
1,2
2,3
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.B32091
230 V single phase
IP44
-5 ÷ +40
3
3Gx1,5 - H07 RN-F
9 + 1
1,2
1,2
2,3
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.B32091
230 V single phase
IP45
-5 ÷ +40
3
3Gx1,5 - H07 RN-F
9 + 1
1,2
1,2
2,3
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.B32091
230 V single phase
IP45
-5 ÷ +40
3
3Gx1,5 - H07 RN-F
9 + 1
1,2
1,2
2,3
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A33091
230 V single phase
IP44
-5 ÷ +40
3
3Gx2,5 - H05 VV-F
9 + 1
1,2
1,9
3,5
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.A33091
230 V single phase
IP44
-5 ÷ +40
3
3Gx2,5 - H05 VV-F
9 + 1
1,2
1,9
3,5
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.A33091
230 V single phase
IP45
-5 ÷ +40
3
3Gx2,5 - H05 VV-F
9 + 1
1,2
1,9
3,5
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.A33091
230 V single phase
IP44
-5 ÷ +40
3
3Gx2,5 - H05 VV-F
9 + 1
1,2
1,9
3,5
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.A33091
230 V single phase
IP45
-5 ÷ +40
3
3Gx2,5 - H05 VV-F
9 + 1
1,2
1,9
3,5
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.A33091
230 V single phase
IP44
-5 ÷ +40
3
3Gx2,5 - H05 VV-F
9 + 1
1,2
1,9
3,5
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.A33091
230 V single phase
IP45
-5 ÷ +40
3
3Gx2,5 - H05 VV-F
9 + 1
1,2
1,9
3,5
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.A33091
230 V single phase
IP45
-5 ÷ +40
3
3Gx2,5 - H05 VV-F
9 + 1
1,2
1,9
3,5
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.B33071
230 V single phase
IP44
-5 ÷ +40
3
3Gx2,5 - H07 RN-F
7 + 1
1,2
1,9
3,5
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A1.B33071
230 V single phase
IP44
-5 ÷ +40
3
3Gx2,5 - H07 RN-F
7 + 1
1,2
1,9
3,5
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A2.B33071
230 V single phase
IP45
-5 ÷ +40
3
3Gx2,5 - H07 RN-F
7 + 1
1,2
1,9
3,5
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A3.B33071
230 V single phase
IP44
-5 ÷ +40
3
3Gx2,5 - H07 RN-F
7 + 1
1,2
1,9
3,5
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A4.B33071
230 V single phase
IP45
-5 ÷ +40
3
3Gx2,5 - H07 RN-F
7 + 1
1,2
1,9
3,5
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,2
728A5.B33071
230 V single phase
IP44
-5 ÷ +40
3
3Gx2,5 - H07 RN-F
7 + 1
1,2
1,9
3,5
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 8,8
728A6.B33071
230 V single phase
IP45
-5 ÷ +40
3
3Gx2,5 - H07 RN-F
7 + 1
1,2
1,9
3,5
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
728A7.B33071
230 V single phase
IP45
-5 ÷ +40
3
3Gx2,5 - H07 RN-F
7 + 1
1,2
1,9
3,5
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 8,8
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A41111
400 V three phase
IP44
-5 ÷ +40
4
4Gx1 - H05 VV-F
11 + 1
1,2
1,1
2,3
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A1.A41111
400 V three phase
IP44
-5 ÷ +40
4
4Gx1 - H05 VV-F
11 + 1
1,2
1,1
2,3
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A2.A41111
400 V three phase
IP45
-5 ÷ +40
4
4Gx1 - H05 VV-F
11 + 1
1,2
1,1
2,3
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A3.A41111
400 V three phase
IP44
-5 ÷ +40
4
4Gx1 - H05 VV-F
11 + 1
1,2
1,1
2,3
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 9
728A4.A41111
400 V three phase
IP45
-5 ÷ +40
4
4Gx1 - H05 VV-F
11 + 1
1,2
1,1
2,3
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A5.A41111
400 V three phase
IP44
-5 ÷ +40
4
4Gx1 - H05 VV-F
11 + 1
1,2
1,1
2,3
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 9
728A6.A41111
400 V three phase
IP45
-5 ÷ +40
4
4Gx1 - H05 VV-F
11 + 1
1,2
1,1
2,3
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 9
728A7.A41111
400 V three phase
IP45
-5 ÷ +40
4
4Gx1 - H05 VV-F
11 + 1
1,2
1,1
2,3
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 9
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A42101
400 V three phase
IP44
-5 ÷ +40
4
4Gx1,5 - H05 VV-F
10 + 1
1,2
1,4
4
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A1.A42101
400 V three phase
IP44
-5 ÷ +40
4
4Gx1,5 - H05 VV-F
10 + 1
1,2
1,4
4
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A2.A42101
400 V three phase
IP45
-5 ÷ +40
4
4Gx1,5 - H05 VV-F
10 + 1
1,2
1,4
4
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A3.A42101
400 V three phase
IP44
-5 ÷ +40
4
4Gx1,5 - H05 VV-F
10 + 1
1,2
1,4
4
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 9
728A4.A42101
400 V three phase
IP45
-5 ÷ +40
4
4Gx1,5 - H05 VV-F
10 + 1
1,2
1,4
4
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A5.A42101
400 V three phase
IP44
-5 ÷ +40
4
4Gx1,5 - H05 VV-F
10 + 1
1,2
1,4
4
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 9
728A6.A42101
400 V three phase
IP45
-5 ÷ +40
4
4Gx1,5 - H05 VV-F
10 + 1
1,2
1,4
4
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 9
728A7.A42101
400 V three phase
IP45
-5 ÷ +40
4
4Gx1,5 - H05 VV-F
10 + 1
1,2
1,4
4
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 9
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.B42081
400 V three phase
IP44
-5 ÷ +40
4
4Gx1,5 - H07 RN-F
8 + 1
1,2
1,4
4
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A1.B42081
400 V three phase
IP44
-5 ÷ +40
4
4Gx1,5 - H07 RN-F
8 + 1
1,2
1,4
4
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A2.B42081
400 V three phase
IP45
-5 ÷ +40
4
4Gx1,5 - H07 RN-F
8 + 1
1,2
1,4
4
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A3.B42081
400 V three phase
IP44
-5 ÷ +40
4
4Gx1,5 - H07 RN-F
8 + 1
1,2
1,4
4
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 9
728A4.B42081
400 V three phase
IP45
-5 ÷ +40
4
4Gx1,5 - H07 RN-F
8 + 1
1,2
1,4
4
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A5.B42081
400 V three phase
IP44
-5 ÷ +40
4
4Gx1,5 - H07 RN-F
8 + 1
1,2
1,4
4
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 9
728A6.B42081
400 V three phase
IP45
-5 ÷ +40
4
4Gx1,5 - H07 RN-F
8 + 1
1,2
1,4
4
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 9
728A7.B42081
400 V three phase
IP45
-5 ÷ +40
4
4Gx1,5 - H07 RN-F
8 + 1
1,2
1,4
4
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 9
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A43081
400 V three phase
IP44
-5 ÷ +40
4
4Gx2,5 - H05 VV-F
8 + 1
1,2
2
6
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A1.A43081
400 V three phase
IP44
-5 ÷ +40
4
4Gx2,5 - H05 VV-F
8 + 1
1,2
2
6
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A2.A43081
400 V three phase
IP45
-5 ÷ +40
4
4Gx2,5 - H05 VV-F
8 + 1
1,2
2
6
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A3.A43081
400 V three phase
IP44
-5 ÷ +40
4
4Gx2,5 - H05 VV-F
8 + 1
1,2
2
6
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 9
728A4.A43081
400 V three phase
IP45
-5 ÷ +40
4
4Gx2,5 - H05 VV-F
8 + 1
1,2
2
6
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A5.A43081
400 V three phase
IP44
-5 ÷ +40
4
4Gx2,5 - H05 VV-F
8 + 1
1,2
2
6
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 9
728A6.A43081
400 V three phase
IP45
-5 ÷ +40
4
4Gx2,5 - H05 VV-F
8 + 1
1,2
2
6
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 9
728A7.A43081
400 V three phase
IP45
-5 ÷ +40
4
4Gx2,5 - H05 VV-F
8 + 1
1,2
2
6
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 9
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.B43051
400 V three phase
IP44
-5 ÷ +40
4
4Gx2,5 - H07 RN-F
5 + 1
1,2
2
6
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A1.B43051
400 V three phase
IP44
-5 ÷ +40
4
4Gx2,5 - H07 RN-F
5 + 1
1,2
2
6
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A2.B43051
400 V three phase
IP45
-5 ÷ +40
4
4Gx2,5 - H07 RN-F
5 + 1
1,2
2
6
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A3.B43051
400 V three phase
IP44
-5 ÷ +40
4
4Gx2,5 - H07 RN-F
5 + 1
1,2
2
6
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 9
728A4.B43051
400 V three phase
IP45
-5 ÷ +40
4
4Gx2,5 - H07 RN-F
5 + 1
1,2
2
6
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A5.B43051
400 V three phase
IP44
-5 ÷ +40
4
4Gx2,5 - H07 RN-F
5 + 1
1,2
2
6
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 9
728A6.B43051
400 V three phase
IP45
-5 ÷ +40
4
4Gx2,5 - H07 RN-F
5 + 1
1,2
2
6
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 9
728A7.B43051
400 V three phase
IP45
-5 ÷ +40
4
4Gx2,5 - H07 RN-F
5 + 1
1,2
2
6
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 9
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A51111
400 V three phase
IP44
-5 ÷ +40
5
5Gx1 - H05 VV-F
11 + 1
1,2
1
2,3
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A1.A51111
400 V three phase
IP44
-5 ÷ +40
5
5Gx1 - H05 VV-F
11 + 1
1,2
1
2,3
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A2.A51111
400 V three phase
IP45
-5 ÷ +40
5
5Gx1 - H05 VV-F
11 + 1
1,2
1
2,3
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A3.A51111
400 V three phase
IP44
-5 ÷ +40
5
5Gx1 - H05 VV-F
11 + 1
1,2
1
2,3
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 9
728A4.A51111
400 V three phase
IP45
-5 ÷ +40
5
5Gx1 - H05 VV-F
11 + 1
1,2
1
2,3
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A5.A51111
400 V three phase
IP44
-5 ÷ +40
5
5Gx1 - H05 VV-F
11 + 1
1,2
1
2,3
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 9
728A6.A51111
400 V three phase
IP45
-5 ÷ +40
5
5Gx1 - H05 VV-F
11 + 1
1,2
1
2,3
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 9
728A7.A51111
400 V three phase
IP45
-5 ÷ +40
5
5Gx1 - H05 VV-F
11 + 1
1,2
1
2,3
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 9
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A52081
400 V three phase
IP44
-5 ÷ +40
5
5Gx1,5 - H05 VV-F
8 + 1
1,2
1,4
4
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A1.A52081
400 V three phase
IP44
-5 ÷ +40
5
5Gx1,5 - H05 VV-F
8 + 1
1,2
1,4
4
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A2.A52081
400 V three phase
IP45
-5 ÷ +40
5
5Gx1,5 - H05 VV-F
8 + 1
1,2
1,4
4
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A3.A52081
400 V three phase
IP44
-5 ÷ +40
5
5Gx1,5 - H05 VV-F
8 + 1
1,2
1,4
4
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 9
728A4.A52081
400 V three phase
IP45
-5 ÷ +40
5
5Gx1,5 - H05 VV-F
8 + 1
1,2
1,4
4
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A5.A52081
400 V three phase
IP44
-5 ÷ +40
5
5Gx1,5 - H05 VV-F
8 + 1
1,2
1,4
4
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 9
728A6.A52081
400 V three phase
IP45
-5 ÷ +40
5
5Gx1,5 - H05 VV-F
8 + 1
1,2
1,4
4
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 9
728A7.A52081
400 V three phase
IP45
-5 ÷ +40
5
5Gx1,5 - H05 VV-F
8 + 1
1,2
1,4
4
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 9
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.B52071
400 V three phase
IP44
-5 ÷ +40
5
5Gx1,5 - H07 RN-F
7 + 1
1,2
1,4
4
yes
-
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A1.B52071
400 V three phase
IP44
-5 ÷ +40
5
5Gx1,5 - H07 RN-F
7 + 1
1,2
1,4
4
yes
yes
-
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A2.B52071
400 V three phase
IP45
-5 ÷ +40
5
5Gx1,5 - H07 RN-F
7 + 1
1,2
1,4
4
yes
-
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A3.B52071
400 V three phase
IP44
-5 ÷ +40
5
5Gx1,5 - H07 RN-F
7 + 1
1,2
1,4
4
yes
-
-
yes
-
-
1 - 0,043
7 ÷ 9
728A4.B52071
400 V three phase
IP45
-5 ÷ +40
5
5Gx1,5 - H07 RN-F
7 + 1
1,2
1,4
4
yes
yes
yes
-
-
-
1 - 0,043
6,4 ÷ 8,4
728A5.B52071
400 V three phase
IP44
-5 ÷ +40
5
5Gx1,5 - H07 RN-F
7 + 1
1,2
1,4
4
yes
yes
-
yes
-
-
1 - 0,043
7 ÷ 9
728A6.B52071
400 V three phase
IP45
-5 ÷ +40
5
5Gx1,5 - H07 RN-F
7 + 1
1,2
1,4
4
yes
-
yes
yes
-
-
1 - 0,043
7 ÷ 9
728A7.B52071
400 V three phase
IP45
-5 ÷ +40
5
5Gx1,5 - H07 RN-F
7 + 1
1,2
1,4
4
yes
yes
yes
yes
-
-
1 - 0,043
7 ÷ 9
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A32142
400 V three phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
-
-
universal Schuko plug
single Schuko plug
1 - 0,043
6,6 ÷ 8,8
728A0.A33092
230 V single phase
IP44
-5 ÷ +40
3
3Gx2,5 - H05 VV-F
9 + 1
1,2
1,9
3,5
yes
-
-
-
universal Schuko plug
single Schuko plug
1 - 0,043
6,4 ÷ 8,2
728A0.B32092
230 V single phase
IP44
-5 ÷ +40
3
3Gx1,5 - H07 RN-F
9 + 1
1,2
1,2
2,3
yes
-
-
-
universal Schuko plug
single Schuko plug
1 - 0,043
6,4 ÷ 8,2
728A1.A32142
400 V three phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
-
-
universal Schuko plug
single Schuko plug
1 - 0,043
6,6 ÷ 8,8
728A2.A32142
400 V three phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
yes
-
universal Schuko plug
single Schuko plug
1 - 0,043
6,6 ÷ 8,8
728A3.A32142
400 V three phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
-
yes
universal Schuko plug
single Schuko plug
1 - 0,043
7,2 ÷ 9,4
728A4.A32142
400 V three phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
yes
-
universal Schuko plug
single Schuko plug
1 - 0,043
6,6 ÷ 8,8
728A5.A32142
400 V three phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
-
yes
universal Schuko plug
single Schuko plug
1 - 0,043
7,2 ÷ 9,4
728A6.A32142
400 V three phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
yes
yes
universal Schuko plug
single Schuko plug
1 - 0,043
7,2 ÷ 9,4
728A7.A32142
400 V three phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
yes
yes
universal Schuko plug
single Schuko plug
1 - 0,043
7,2 ÷ 9,4
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Max power use (20 °C) woundkW
Max power use (20 °C) unwoundkW
Thermal protector
Rewinding clutch
Protection cap
Bayonet bracket
Socket
Plug
PackingN° - m3
Gross weightkg
Docs
728A0.A32143
400 V three phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
-
-
Schuko
triple Schuko plug
1 - 0,043
6,6 ÷ 8,8
728A1.A32143
400 V three phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
-
-
Schuko
triple Schuko plug
1 - 0,043
6,6 ÷ 8,8
728A2.A32143
400 V three phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
yes
-
Schuko
triple Schuko plug
1 - 0,043
6,6 ÷ 8,8
728A3.A32143
400 V three phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
-
yes
Schuko
triple Schuko plug
1 - 0,043
7,2 ÷ 9,4
728A4.A32143
400 V three phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
yes
-
Schuko
triple Schuko plug
1 - 0,043
6,6 ÷ 8,8
728A5.A32143
400 V three phase
IP44
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
-
yes
Schuko
triple Schuko plug
1 - 0,043
7,2 ÷ 9,4
728A6.A32143
400 V three phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
-
yes
yes
Schuko
triple Schuko plug
1 - 0,043
7,2 ÷ 9,4
728A7.A32143
400 V three phase
IP45
-5 ÷ +40
3
3Gx1,5 - H05 VV-F
14 + 1
1,2
1,2
2,3
yes
yes
yes
yes
Schuko
triple Schuko plug
1 - 0,043
7,2 ÷ 9,4
Information
Protection degree of electrical part
Environment temperature°C
Number of conductors
Cable type
Cable lengthm
Cable inletm
Inlet voltage
Lamp power supply voltage
Lamp connection
Max powerW
Lamp protection degree
Light bulb suppliedP/N
Rewinding clutch
Protection cap
Bayonet bracket
Lamp
PackingN° - m3
Gross weightkg
Docs
728A0.C21141
without transformer
IP44
-5 ÷ +40
2
2x1 - H05 RN-F
14 + 1
1,2
230 V AC - 50 Hz
-
-
-
-
-
-
-
-
-
1 - 0,043
6,8 ÷ 8,8

IDFamiglia = 45


     

Those RAASM cable reels with an extension allow for the connection of electric tools and systems of between 230 V and 400 V, with and without Schuko socket. Available in different lengths and with accessories including a rewinding clutch, bayonet bracket and protection hood, these items are indispensable when it comes to keeping a work environment safe and organised. All models also have a heat guard and hose guide with 4 rollers as standard, and are certified with an electrical parts protection grade equal to IP44.

ENG
Descrizione Breve: 
The cable reel with extension and/or Schuko socket is an effective and safe product with which to connect electrical equipment to the grid even in the dustiest and toughest of working environments.
Foto(URL): 
Foto/728A0.A22151.jpg
Settore Aeronautica: 
Settore Agricoltura: 
Macrofamiglia: 
Cable reels
Tipologia Fluido: 
Electricity
Settore Automotive: 
Settore Veicoliindustriali: 
Settore Cleaning: 
Settore Edilizia: 
Settore TrasportiFerroviari: 
Settore IndustriaChimica: 
Settore IndustriaManifatturiera: 
Settore LubrificazioneCentralizzata: 
Settore Navale: 
Settore IndustriaMineraria: 
Brochure Promozionale: 
BrochurePromozionale\Inglese\Avvolgicavo\WRCAVVC2015-GB RAASM Cat avvolgicavo N 222-AE bassa.pdf
Video: 
Video/carico scarico molla avvolgicavo.mp4
ID Famiglia: 
45
Video 2: 
Video/Montaggio tubo Avvolgitubo.mp4
Video 3: 
Video/Smontaggio tubo.mp4
Video 4: 
Video/Nuovo sistema di sicurezza per avvolgitubo manuali - New safety system for manual hose reel.mp4
Scheda Prodotto: 
SchedaProdotto/Italiano/18_WRCAVVC2015-I RAASM Cat avvolgicavo N 222-AE bassa .pdf
Posizione: 
1
parole di ricerca: 
Cable reel - extension, cable reel with extension, cable reel extension, cable reel, cable reels, extension, extensions, electric cable reel, electric cable reels, electric, 728A0.A21171, 728A1.A21171, 728A2.A21171, 728A3.A21171, 728A4.A21171, 728A5.A21171, 728A6.A21171, 728A7.A21171, 728A0.B21121, 728A1.B21121, 728A2.B21121, 728A3.B21121, 728A4.B21121, 728A5.B21121, 728A6.B21121, 728A7.B21121, 728A0.A22151, 728A1.A22151, 728A2.A22151, 728A3.A22151, 728A4.A22151, 728A5.A22151, 728A6.A22151, 728A7.A22151, 728A0.A23101, 728A1.A23101, 728A2.A23101, 728A3.A23101, 728A4.A23101, 728A5.A23101, 728A6.A23101, 728A7.A23101, 728A0.A31141, 728A1.A31141, 728A2.A31141, 728A3.A31141, 728A4.A31141, 728A5.A31141, 728A6.A31141, 728A7.A31141, 728A0.B31101, 728A1.B31101, 728A2.B31101, 728A3.B31101, 728A4.B31101, 728A5.B31101, 728A6.B31101, 728A7.B31101, 728A0.A32141, 728A1.A32141, 728A2.A32141, 728A3.A32141, 728A4.A32141, 728A5.A32141, 728A6.A32141, 728A7.A32141, 728A0.B32091, 728A1.B32091, 728A2.B32091, 728A3.B32091, 728A4.B32091, 728A5.B32091, 728A6.B32091, 728A7.B32091, 728A0.B32092, 728A0.A33091, 728A1.A33091, 728A2.A33091, 728A3.A33091, 728A4.A33091, 728A5.A33091, 728A6.A33091, 728A7.A33091, 728A0.A33092, 728A0.B33071, 728A1.B33071, 728A2.B33071, 728A3.B33071, 728A4.B33071, 728A5.B33071, 728A6.B33071, 728A7.B33071, 728A0.C21141 , 728A0.A41111, 728A1.A41111, 728A2.A41111, 728A3.A41111, 728A4.A41111, 728A5.A41111, 728A6.A41111, 728A7.A41111, 728A0.A42101, 728A1.A42101, 728A2.A42101, 728A3.A42101, 728A4.A42101, 728A5.A42101, 728A6.A42101, 728A7.A42101, 728A0.B42081, 728A1.B42081, 728A2.B42081, 728A3.B42081, 728A4.B42081, 728A5.B42081, 728A6.B42081, 728A7.B42081, 728A0.A43081, 728A1.A43081, 728A2.A43081, 728A3.A43081, 728A4.A43081, 728A5.A43081, 728A6.A43081, 728A7.A43081, 728A0.B43051, 728A1.B43051, 728A2.B43051, 728A3.B43051, 728A4.B43051, 728A5.B43051, 728A6.B43051, 728A7.B43051, 728A0.A51111, 728A1.A51111, 728A2.A51111, 728A3.A51111, 728A4.A51111, 728A5.A51111, 728A6.A51111, 728A7.A51111, 728A0.A52081, 728A1.A52081, 728A2.A52081, 728A3.A52081, 728A4.A52081, 728A5.A52081, 728A6.A52081, 728A7.A52081, 728A0.B52071, 728A1.B52071, 728A2.B52071, 728A3.B52071, 728A4.B52071, 728A5.B52071, 728A6.B52071, 728A7.B52071, 728A0.A32142, 728A1.A32142, 728A2.A32142, 728A3.A32142, 728A4.A32142, 728A5.A32142, 728A6.A32142, 728A7.A32142, 728A0.A32143, 728A1.A32143, 728A2.A32143, 728A3.A32143, 728A4.A32143, 728A5.A32143, 728A6.A32143, 728A7.A32143